Mafron R-410A

RC_PROD_032

/

Mafron

/

Refrigerant Gases & Piping

Mafron R-410A is the near-azeotropic 50/50 blend of R-32 and R-125, the standard for modern residential and light-commercial AC. Genuine NFIL cylinders.

Mafron R-410A is the 50/50 near-azeotropic blend of R-32 and R-125 that became the world standard for modern residential and light-commercial air conditioning. With negligible temperature glide (<0.2 K) it behaves like a single-component fluid in service, and its high volumetric capacity enabled the compact, efficient AC equipment now installed across India in vast numbers — all of which needs genuine service gas.

The critical service fact: R-410A operates at roughly 50–60% higher pressures than R-22. It is exclusively for equipment designed for it — never a retrofit gas for R-22 systems — and demands R-410A-rated gauges, hoses, and recovery equipment. POE lubricant only.

Also asked for as: R410A gas, R410 gas, HFC-410A, "pink cylinder" gas (the industry colour code), and by the trade names used by other manufacturers — all the same AHRI 700 fluid.

Where it is used: split, cassette, ducted and multi-split air conditioners; VRF and VRV systems; heat pumps; packaged rooftop units; and light-commercial chillers built in the R-410A generation — a very large share of everything installed in Indian commercial buildings over the past fifteen years.

Charge it as liquid, and only into R-410A equipment. Although the glide is negligible, the blend is still charged liquid-phase as standard practice. Never put R-410A into a system designed for R-22 or R-407C: the design pressures are not there and the failure is not gradual. Use gauges and hoses rated for R-410A, and remember the oil is POE — handle it as moisture-sensitive and fit a fresh drier whenever the system is opened.

A note on where the market is going: new equipment is increasingly built for R-32 rather than R-410A, but the installed R-410A base is enormous and will need service gas for many years. Buying genuine, certificate-backed cylinders for that base is straightforwardly cheaper than replacing compressors damaged by contaminated gas.

Order Mafron R-410A when a split, VRF or packaged AC system needs recharging after a leak repair, coil change or compressor replacement, when commissioning R-410A equipment, or when a facilities team wants traceable stock on site. Tell us the total charge you need and we will confirm cylinder availability.

ASHRAE Safety Class A1

zero ODP; negligible glide (<0.2 K)

Installed-base service standard

for modern split, VRF, and packaged AC

AHRI 700 guaranteed purity

certified purity sheets directly from Navin Fluorine (NFIL)

High volumetric capacity

high pressure requires R-410A-rated equipment

Specifications

ASHRAE designation

R-410A

Composition (wt%)

R-32 / R-125 — 50 / 50 (± component tolerances per AHRI 700)

Guaranteed purity

≥ 99.5% by weight (blend total)

Supplied across India from our Mumbai warehouse. Request a quotation for pricing and availability.